MAC TOOLS MW250 Instruções de Operação Página 161

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 405
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 160
TM 5-4310-452-14
4-53. AMMETER REPLACEMENT.
This Task Covers:
a. Removal b. Installation
Initial Setup:
Equipment Conditions: Tools/Test Equipment:
Engine off. General mechanic's tool kit
Left door assembly open.
Battery cables disconnected (see paragraph
4-57).
a. REMOVAL
1. Remove window (see paragraph 4-55).
2. Remove 2 nuts (5), washers (6), and electrical leads
(7) from ammeter (1).
3. Remove 2 knurled nuts (4) and retainer (3) from
ammeter (1).
4. Remove ammeter (1) from indicator panel (2).
b. INSTALLATION
1. Position ammeter (1) in place in indicator panel (2).
2. Install retainer (3) and 2 knurled nuts (4) on ammeter (1).
3. Install 2 electrical leads (7), washers (6), and nuts (5) on ammeter (1).
4. Install window (see paragraph 4-55).
FOLLOW-ON TASKS:
Connect battery cables (see paragraph 4-57).
Close left door assembly.
TA505484
4-99
Vista de página 160
1 2 ... 156 157 158 159 160 161 162 163 164 165 166 ... 404 405

Comentários a estes Manuais

Sem comentários